• Frm02 Relay Module Delay Auto-Lock Cycle Timing Relay Module 18 Kinds of Functions Can Be Set DIY RC Toy Kit
  • Frm02 Relay Module Delay Auto-Lock Cycle Timing Relay Module 18 Kinds of Functions Can Be Set DIY RC Toy Kit
  • Frm02 Relay Module Delay Auto-Lock Cycle Timing Relay Module 18 Kinds of Functions Can Be Set DIY RC Toy Kit
  • Frm02 Relay Module Delay Auto-Lock Cycle Timing Relay Module 18 Kinds of Functions Can Be Set DIY RC Toy Kit

Frm02 Relay Module Delay Auto-Lock Cycle Timing Relay Module 18 Kinds of Functions Can Be Set DIY RC Toy Kit

Theory: Electromagnetic Relay
Usage: Household Appliances Relay, Communication Relay, Lathe Relay
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
FRM02
HS Code
8543709990

Product Description

Description:

FRM02 Two Way Multi-Function Relay Module Delay Self-Locking Cycle Robot DIY RC Electronic Toy Robot

FRM02 type 2 channel relay control module,designed for a variety of different needs of users, the micro controller as themain control unit, as many as 18 kinds of preset functions, and can accordingto user requirements, customize and add other specific functions.

Module adopts quality goods of high quality power relay, high power high pressuretriode, red, blue light signal, HIGH level double-sided PCB board, clothplate considering comprehensive, stable performance and can be widely used invarious power control occasions.

 

Have 2 channel input and output control, each channel can be setup respectively 18 kinds of function, meet the demand of more applications;

Have the function of power meter, won't because of wrong damageof power supply module;

With top quality and high pressure power module, system morestable and reliable;

Can be set to at least 0.1 seconds time function, timing accuracyis better than the 0.01 seconds;

Increase the automatic power saving function, users can set byoneself;

All Settings, can automatically save, set the content is not lostwhen power supply drop.

 

Function

1, after poweron, relay delay or absorption, clockwise (adjustable resistance can increase

Users canthrough the buttons and display, select the following one of 18 kinds offunctions, can be set and save function parameter, you can also view thecurrent function parameters, adjustable parameter is set minimum 0.1 seconds,the accuracy is better than that of 0.01 seconds, on specific set ofinstructions, after purchase to the seller for the electronic "FRM02 usersmanual".

Warm prompt: will automatically start when the electricity function 1-8,function 9 to 18 need high level pulse signal to trigger the start (high levelduration is not less than 20 ms, the same below), 9 is the function of the lockmode, the function is 10 level control mode.

Feature 1:

Timing and: after electricity, delay the T1 time relay, adjustable between T1in 0.1 seconds - 270 hours, CH1 interface to a high level pulse signal, repeatthe above function;

Feature 2:

Regularly disconnect: the electric relay or absorption, delay the T1 time relaydisconnect, adjustable between T1 in 0.1 seconds - 270 hours, CH1 interface toa high level pulse signal, repeat the above function;

Feature 3:

Timing and then disconnect: after electricity, relay not suck first, delay timeT1 arrival relay; And off time T2 relay disconnected upon arrival, delay timebetween T1 and T2 in 0.1 seconds - 270 hours is adjustable, CH1 interface to ahigh level pulse signal, repeat the above function;

Features 4:

Regularly disconnect again and: after electricity, relay and off immediately,delay time T1 arrival relay disconnected; Turn off time T2 relay and uponarrival, delay time between T1 and T2 in 0.1 seconds - 270 hours is adjustable,CH1 interface to a high level pulse signal, repeat the above function;

Function of 5:

Infinite loop timing pattern 1: electricity, relay not suck first, delay timeT1 arrival relay; And off time T2 relay disconnected upon arrival, and thenrepeat the above condition, delay time between T1 and T2 in 0.1 seconds - 270hours is adjustable, CH1 interface to a high level pulse signal, can startagain above functions;

Features 6:

Infinite loop timing mode 2: after electricity, relay and off immediately,delay time T1 arrival relay disconnected; Turn off time T2 relay and uponarrival, and then repeat the above condition, delay time between T1 and T2 in0.1 seconds - 270 hours is adjustable, CH1 interface to a high level pulsesignal, can start again above functions;

Function 7:

After limited cycle timing pattern 1: electricity, relay not suck first, delaytime T1 arrival relay; Off time T2 relay disconnected upon arrival, and thenrepeat above NX times, at this time between T1 and T2 in 0.1 seconds - 9999seconds, adjustable cycles NX adjustable between 1-9999 times, CH1 interface toa high level pulse signal, can start again above functions;

Function 8:

After limited cycle timing mode 2: electricity, relay and off immediately,delay time T1 arrival relay disconnected; Trip time T2 relay and upon arrival,and then repeat above NX times, at this time between T1 and T2 in 0.1 secondsto 9999 seconds, adjustable cycles NX adjustable between 1-9999 times, CH1interface to a high level pulse signal, can start again above functions;

Function of 9:

Latching relay mode: relay CH1 interface to a high level pulse signal, relay orabsorption, give a high level pulse signal relay disconnect.

Function of 10:

Trigger relay mode: including delay off function, the electric relay action,after the CH1 interface to a high level signal, relay and off immediately, CH1signal disappears, relay and still, when T1 and time relay disconnect after hearrived, the T1 adjustable between 0 seconds - 270 hours.

Note: this function, if the T1 is set to 0 seconds, becomes: CH1 a high levelsignal relay or absorption, no signal is disconnected immediately.

Function of 11:

On the trigger timing and: after electric relay not action, CH1 interface to ahigh level pulse signal, delay the T1 time relay, adjustable between T1 in 0.1seconds - 270 hours, repeat CH1 interface to a high level pulse signal, repeatthe above function;

Features 12:

On the trigger timing disconnect: after electric relay action, CH1 interface toa high level pulse signal, relay and, delay the T1 time relay disconnect,adjustable between T1 in 0.1 seconds - 270 hours, repeat CH1 interface to ahigh level pulse signal, repeat the above function;

Function of 13:

On the trigger timing and then disconnect: after electric relay action, CH1interface to a high level pulse signal, delay time T1 arrival relay; And offtime T2 relay disconnected upon arrival, delay time between T1 and T2 in 0.1seconds - 270 hours is adjustable, repeat CH1 interface to a high level pulsesignal, repeat the above function;

Function of 14:

On the trigger timing disconnect again and: after electric relay action, CH1interface to a high level pulse signal, relay and off immediately, delay timeT1 arrival relay disconnected; Turn off time T2 relay and upon arrival, delaytime between T1 and T2 in 0.1 seconds - 270 hours is adjustable, repeat CH1interface to a high level pulse signal, repeat the above function;

Features 15:

On the infinite loop timing pattern 1: electric relay action, after CH1interface to a high level pulse signal, delay time T1 arrival relay; And offtime T2 relay disconnected upon arrival, and then repeat the above condition,delay time between T1 and T2 in 0.1 seconds - 270 hours is adjustable, repeatCH1 interface to a high level pulse signal, can start again above functions;

Function of 16:

Infinite loop timing mode 2: after power on relay action, CH1 interface to ahigh level pulse signal, relay and off immediately, delay time T1 arrival relaydisconnected; Turn off time T2 relay and upon arrival, and then repeat theabove condition, delay time between T1 and T2 in 0.1 seconds - 270 hours isadjustable, repeat CH1 interface to a high level pulse signal, can start againabove functions;

Features 17:

Limited cycle timing pattern 1: the electric relay action, after the CH1interface to a high level pulse signal, the delay time T1 arrival relay; And T2time relay disconnected upon arrival, and then repeat above NX times, at thistime between T1 and T2 in 0.1 seconds to 9999 seconds, adjustable cycles NXadjustable between 1-9999 times, repeated CH1 interface to a high level pulsesignal, can start again above functions;

Features 18:

Limited cycle timing mode 2: after power on relay action, CH1 interface to ahigh level pulse signal, relay and off immediately, delay time T1 arrival relaydisconnected; Turn off time T2 relay and upon arrival, and then repeat above NXtimes, at this time between T1 and T2 in 0.1 seconds to 9999 seconds isadjustable, cycles NX adjustable between 1-9999 times, repeated CH1 interfaceto a high level pulse signal, can start again above functions;

Two electrical parameters

Working voltage: dc 5 v, 12 v, 24 v three optional (should not exceed thenominal voltage of + / - 10%)

When working current: 5 v is less than 180 ma (relay action not less than 15ma, closed showed less than 3 ma)

12 v is less than 90 ma (relay action not less than 15 ma, closed showed lessthan 3 ma)

24 v is less than 60 ma (relay action not less than 15 ma, closed showed lessthan 3 ma)

Working temperature: recommended - 20 deg to 60 deg (limit workingtemperature range - 30 deg, 70 deg)

Load capacity: relay often start mouth maximum load capacity: dc 0 to 30 v / 10a, 0-250 - v / 10 a communication

Relay normally closed port maximum load capacity: dc 0 to 28 v / 10 a, 0-125 -v / 10 a communication

 

Three module interface:

Voltage/signal input module: there are 3 line interface, all interfaces areterminal blocks, convenience for the user

1, the DC + : DC power to the anode

2, DC - : negative DC power supply

1 3, CH1: input signal detection interface

4, CH2: input signal detection interface 2

Relay load output: there are 3 line interface, all interfaces have terminalblocks

1, no. : the first relay all the way open interfaces, often before the relayand impending, after absorption and COM1 short answer

2, COM1: the first relay all the way the public interface

3, NC1: the first relay all the way normally closed interface, relay and withshort COM1, before and after the impending

4, NO2: normally open interface of the first two relays, relay and impending,before and after absorption and COM2 short answer

5, COM2: public interface of the first two relays

6, NC2: the first two relays normally closed interface, relay with short beforeand COM2, dangling after absorption

 

Four module size:

1. The shape size: 77 mm * 50 mm * 20 mm (length * width * height)

2. The screw hole size: 4 * phi 3.0 mm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2011

Suppliers with verified business licenses

Trading Company
Number of Employees
22
Year of Establishment